Quantum-composers 9500 Plus Series Manual do Utilizador Página 1

Consulte online ou descarregue Manual do Utilizador para Geradores Quantum-composers 9500 Plus Series. Quantum Composers 9500 Plus Series User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Operating Manual

9500 PPlluuss Series & 8510 Board Level Pulse Generator Operating Manual V1.2 QUANTUM COMPOSERS, INC 212 Discovery Drive Bozeman, MT 597

Página 2 - Contents

6 Front Panel Overview (Not applicable towards the 8510 board level series) 9500+ Front Panels Display Layout and Indicators A 4 line

Página 3

7 • Numeric Keypad Allows numbers and alphanumeric values to be entered. When entering alphanumeric values, pressing a key will

Página 5 - Introduction

9 3 Pulse Concepts and Pulse Generator Operations

Página 6

10 * St art source is: RUN but ton in Internal Modes Ex ternal input in External trigger modes ** Channels are armed by the RUN but ton.

Página 7

11 Channel Timer Functions The Channel Timer functions as a non-retriggerable, delayed, one shot pulse generator. This means that the tim

Página 8 - 4

12 Menus may include a number of different pages in which each page contains up to four parameters. The status block in the upper-left corner

Página 9

13 • 3 D E F d e f 3 • 4 G H I g h i 4 • 5 J K L j k l 5 • 6 M N O m n o 6 • 7 P Q R S p q r s 7 • 8 T U V t u v 8 • 9 W X Y Z

Página 10 - Front Panel Overview

14 Out: Selects between TTL/CMOS mode and Adjustable mode output. Pol: Sets the polarity of the pulse, active high or active low. Note: All

Página 11 - 7

15 4 9500+ Menus

Página 12 - 8

Contents 1 Introduction ... 1 Technical Support ...

Página 13 - Pulse Generator Operations

16 9500+ Menus (Physical access of any display menu is not possible on the 8510 board level series.) 9500+ Menu Structure System MO

Página 14 - Pulse Generator Operation

17 SYSTEM Menus Comm. Parameters Keypad Parameters Misc. Parameters Baud Rate Key Repeat Rate Auto Start Echo Enable Key Volume Dec

Página 15

18 System Mode Menu To Mode To Mode To Mode To Mode MODE: Continuous MODE: Single Shot MODE: Bu

Página 16

19 Setting the Channel Timing Parameters To define a pulse requires three parameters: The sync source, the delay to the active edge, and t

Página 17

20 Enables the gate by selecting either active high or active low. This function is independent of any other use of the trigger input. Care s

Página 18 - 14

21 Gate/Trig Menu Gate/Trigger Mode Gate/Trigger Mode Gate/Trigger Mode MODE: Disabled MODE: Triggered MODE

Página 19 - 9500+ Menus

22 Setting Keypad Parameters The rate at which a key will repeat itself when pressed down may be set. This can be used to provide a controlle

Página 21 - 17

24 Recall Menu Recall Menu Configuration # Name Help Line Recalling System Configurations Use the following procedure to recall a stor

Página 23 - 19

Delaying the Start of Channel Output ... 20 Rate Menu ...

Página 24 - Rate Menu

26 5 Operating the 9500+

Página 25 - System Menu

27 Operating the 9500+ Quick Start - Normal Internal Rate Generator Operation The 9500+ has a powerful set of functions providing a

Página 26 - Store Menu

28 Edge: Press the NEXT key until the Edge parameter is high- lighted. Set the instrument to trigger off the rising edge or falling edge a

Página 27 - 23

29 To Use System Burst Mode Function The RUN/STOP button generates a stream of "n" T0 pulses, where "n" is specified

Página 28 - Recall Menu

30 Pressing the RUN/STOP key will now generate a continuous stream of pulses. To Use Channel Single Shot Function The Single Shot mode gene

Página 29 - 25

31 To Use the Channel Gating Function Each channel may use the external input to gate or control its output. The gate controls the triggering

Página 30 - Operating the 9500+

32 - Within the Rate menu Per: Set the period between pulses. - Within the Gate/Trig menu EXTin: Select Triggered mode. Level: Set the t

Página 31

33 - Within the Gate/Trig menu EXTin: Select Gated mode. Level: Set the gate threshold level. Gate: Select active high or active low. Pre

Página 32

34 6 Programming the 9500+

Página 33

35 Programming the 9500+ Personal Computer to Pulse Generator Communication The 9500+ comes standard with an RS232 serial interface, USB

Página 34 - 30

SCPI Command Keywords ... 37 SCPI Command Format ...

Página 35

36 USB Interface Overview The USB interface is standard on the 9500+. Before this type of communication can be used, the appropriate drivers

Página 36 - 32

37 Ethernet Interface Overview An Ethernet interface is optional on the 9500+. When this option is chosen, the USB port is replaced by the Et

Página 37 - 33

38 Line Termination The pulse generator uses text-style line terminations. When a command is sent to the unit, the firmware is programmed to

Página 38 - Programming the 9500+

39 For example, if the command keyword is given as POLarity, then POL and POLARITY are both acceptable forms; truncated forms such as POLAR w

Página 39

40 SCPI Specific and Implied Channel Some commands, such as PULSe, allow specifying a channel with an optional numeric keyword suffix. The su

Página 40 - USB Interface Overview

41 Programming Examples Example 1) 20 ms pulsewidth, 2.3 ms delay, 10 Hz, internal trigger, continuous operation. :PULSE1:STATE ON <cr>

Página 41

42 9500+ SCPI Command Summary Keyword Lower-Level Keyword Parameter Std / New Comments :INSTrument Std Subsystem. Supports treating

Página 42

43 9500+ SCPI Command Summary Keyword Lower-Level Keyword Lower-Level Keyword Parameter Std / New Comments :SPULSe St

Página 43

44 9500+ SCPI Command Summary Keyword Lower-Level Keyword Lower-Level Keyword Parameter Std / New Comments :PULSe [1 / 2 / n] Std Subs

Página 44

45 9500+ SCPI Command Summary Keyword Lower-Level Keyword Lower-Level Keyword Lower-Level Keyword Parameter Std / New Comments :SYSTem S

Página 45

1 1 Introduction

Página 46

46 Keyword Lower-Level Keyword Parameter Std / New Comments :DISPlay Std Subsystem. Contains commands to control the display. :MODe 0 /

Página 48 - 44

48 Appendix

Página 49 - 45

49 Appendix A - Specifications 9500+ Specifications CHANNELS 2, 4 or 8 independent outputs, with digitally con- trolled delay and pul

Página 50 - IEEE 488.2 Common Commands

50 AMPLITUDE Adjustable Mode: 1 - 10 V into 50 Ohms load 2 - 20 V into high impedance load Typical Performance in TTL/CMOS Mode: ~ 1.7 V int

Página 51 - 47

51 Appendix B - Special Functions 35 Volt Output For units with the optional 35 volt output, additional BNC connectors are pro- vided

Página 52 - Appendix

52 T Option System Period The minimum period is 50 ns (20 MHz max frequency). The maximum period is 10 s (.1 Hz frequency). Pulse Range Li

Página 53 - Appendix A - Specifications

53 o The “Clock Out” BNC connector will output a signal dependent on the current configuration. If the “Clock In” parameter is enabled, the 1

Página 54 - 50

54 Clock IN / Clock Out Signal Specifications Frequency: 10 MHz +/-25 PPM Duty Cycle: 50% +/-5% Level (In & Out): TTL/CMOS Deviatio

Página 55 - 35 V Specifications

55 There are two incrementing modes, Increment and DC Increment. In the Increment mode, each start command or external trigger produces a bur

Página 56

2 Introduction This manual is a reference designed to familiarize you with the Quantum Com- posers 9500+ pulse generator and is arranged s

Página 57 - 53

56 replaces the internal clock and allows multiple pulse generators to share the same clock. Function-CLR: Pressing the ‘FUNCTION’ key then

Página 58 - System Mode: Increment

57 :PULSe0:OCOunter # Added Off Counts command to set the number of on/Off pulses to generate in DC Increment mode. :PULSe0:CYCLe # Added

Página 59 - Reference Clock

58 Specifications New Input Optoisolated Voltage 2v to 15v Current 4 mA

Página 60

59 Appendix C - COM Ethernet Interface Overview An Ethernet interface is optional on the 9500+. When this option is chosen, the USB port

Página 61 - Trigger/Gate Option

60 Programming Command Types and Format The 9500+ pulse generator uses two types of programming commands: IEEE 488.2 Common Commands and Stan

Página 62 - 58

61 Appendix D – 8510 Option 8510 Board Level Overview The 8510 is a board level, digital pulse generator based on the 9500+ series in terms

Página 63 - Appendix C - COM

62 Board Level Connection Information Please refer to the standard user’s manual for operation of the unit and how the connections work.

Página 64 - 60

63 • USB Type B USB Connection (J21) Number Name 1 USB Vbus + 2 USB Data- 3 USB Data+ 4 USB Ground • Standard IEE

Página 65 - Appendix D – 8510 Option

64 • Molex 2 pin female C-grid (Molex #50-57-9402). Contacts, Molex External Trigger/Gate (J3) #16-02-0103. Number Name 1 Trigg

Página 66 - 62

65 Figure 1 – 8510 Mechanical Interface

Página 67 - 63

3 Safety Issues Normal use of test equipment presents a certain amount of danger from electrical shock because testing must be performed wher

Página 68 - 64

66 Figure 2 – Component/Connector layout

Página 70 - 66

5 2 Front Panel Overview

Modelos relacionados 8510

Comentários a estes Manuais

Sem comentários