System Pulse Commands
Subsystem. Contains commands to control the
output pulse generation. Commands without suffix
refer to the currently selected logical instrument.
See INSTrument subsystem.
Enables / Disables the output for all channels.
Command is the same as pressing the RUN/STOP
button.
Sets the T
0
period in seconds.
Sets the T
0
generation mode.
DIS / T0 / CHA
/ CHB / etc.
Sets the pulse source for the front panel sync
output.
DIS / T0 / CHA
/ CHB / etc.
Sets the pulse source for the rear panel sync
output.
Contains the commands to define the Trigger
function.
Sets Trigger Mode. Disable or TRIG (enable).
Switches the system trigger source between front
or rear panel inputs.
Selects which edge (rising or falling) to use as the
trigger signal.
Sets the Trigger Threshold. Value is in volts, with a
resolution of .1 Volts.
Enables/Disables the trigger pulse width filter.
Sets the trigger minimum pulse width value in
microseconds.
Contains commands to manipulate the system shot
counter (T
0
pulses)
Enables/Disables the system shot counter.
Clears the system shot counter.
Query Only. Returns the value of the system shot
counter.
Query Only: Returns the measured resistance
value for all channel with PreTest enabled in the
form of <n>:x.xx with each channel separated by a
single space (e.g. 1:1.99 2:2.00 4:2.01 if all
channels except channel 3 have PreTest Enabled)
Query Only: Returns the measured resistance value
for all channel with PostTest enabled in the form of
<n>:xxx.xx with each channel separated by a single
space (e.g. 1:149.99 2:147.00 4:150.01 if all
channels except channel 3 have PostTest Enabled)