8-18 | P a g e
LDDC/LSC Command Summary
Diode Controller address which is
required before any/all subsequent
commands.
Sets and/or queries the burst count
feature.
Query Only. Returns the Crowbar
status.
0 to max
current(up to 3
decimal places)
Query Only. Returns the Current
Measurement.
Sets and/or queries the Current Setting
(Up to three decimal places).
Sets and/or queries the Compliance
Voltage (Up to one decimal place).
Sets and/or queries percentage duty
cycle of pulsed output.
(1)
0 = Custom
1 = LDD<2000W
2 = LDD>2000W
3 = LDDHC
4 = LDDQCW-50
5 = LDDQCW>50
6 = LDY
7 = LDYHC
8 = XLB
9 = LDQPC
10 = LDPC
Sets and/or queries the type of external
Lumina Diode Driver.
Sets and/or queries the Enable signal.
Bypasses and/or queries the external
interlock control so it is always in a
closed or shorted state.
Sets and/or queries Interlock Control
feature.
Ex: Quantum
Composers,1550,
1234,0.21.
Identification. Will return an
identification string in the format of
“Company,Model,Serial
number,Firmware version”.
Sets and/or queries the Maximum
Current (Refer to Diode Driver section)
Comentários a estes Manuais