9-28
Verify the rear panel Safety Interlock.
Turn Arm Switch to ‘ARM’ Position.
Press the FUNC key and then the PRE key (‘.’ on the numeric keypad) to run the
pre pulse resistance test.
Refer to Testing Mode Error Conditions for more information on any resulting
errors.
Post Pulse Resistance Testing
The 9730 allows the user to setup a post pulse resistance test that, when enabled, may
be run at any time to verify the resistance of the connected load is greater than a user
specified minimum. To use pre pulse resistance testing:
Setup the system mode, period and channel pulse parameters as described in
the Standard Operation Modes section.
In the Channel Test Menu:
o Set PstTest to ‘Enabled’
o Set PstMin to the minimum resistance expected for a “fired” device.
Verify the rear panel Safety Interlock.
Turn Arm Switch to ‘ARM’ Position.
Press the FUNC key and then the POST key (‘.’ on the numeric keypad) to run
the post pulse resistance test.
Refer to Testing Mode Error Conditions for more information on any resulting
errors.
Testing Mode Error/Status Conditions
Status - “No Error Detected” – This message is returned through a channel
error query whenever no errors are detected for the current channel. Refer to
Channel Commands for more information channel queries.